Optimization Of Ligament Parameters On A Subject Specific Computational Human Knee Model In A Dynamic Knee Simulator Using Design Of Experiments

Download Optimization Of Ligament Parameters On A Subject Specific Computational Human Knee Model In A Dynamic Knee Simulator Using Design Of Experiments full books in PDF, epub, and Kindle. Read online free Optimization Of Ligament Parameters On A Subject Specific Computational Human Knee Model In A Dynamic Knee Simulator Using Design Of Experiments ebook anywhere anytime directly on your device. Fast Download speed and no annoying ads. We cannot guarantee that every ebooks is available!

Optimization of Ligament Parameters on a Subject-specific Computational Human Knee Model in a Dynamic Knee Simulator Using Design of Experiments

Optimization of Ligament Parameters on a Subject-specific Computational Human Knee Model in a Dynamic Knee Simulator Using Design of Experiments
Author :
Publisher :
Total Pages : 68
Release :
ISBN-10 : OCLC:800409008
ISBN-13 :
Rating : 4/5 ( Downloads)

Book Synopsis Optimization of Ligament Parameters on a Subject-specific Computational Human Knee Model in a Dynamic Knee Simulator Using Design of Experiments by : Paul Michael Wilson

Download or read book Optimization of Ligament Parameters on a Subject-specific Computational Human Knee Model in a Dynamic Knee Simulator Using Design of Experiments written by Paul Michael Wilson and published by . This book was released on 2011 with total page 68 pages. Available in PDF, EPUB and Kindle. Book excerpt: The objective of this study was to optimize ligament parameters used in a dynamic three dimensional subject-specific computational knee model. The parameters of interest are the zero load length (L0), stiffness (k) and the strain level where the force length relationship of the ligament goes from the nonlinear "toe" region to the linear region (epsilon sub l). Experimental testing was performed at the University of Kansas Experimental Joint Biomechanics Research Laboratory (Lawrence, Kansas) in the Kansas Knee Simulator (KKS) under various loading profiles while the kinematics of the knee was recorded. A model of the knee in the KKS was created using previously validated modeling techniques. The experimental and model simulation kinematics for a ten second walk cycle were compared in a two level partial factorial design and a three level full factorial design and the ligament parameters were optimized based on the kinematic RMS error. The resulting parameter values are 80% of the experimentally derived zero load length values, 99.71% of the published ligament stiffness values, and 100% of the published epsilon sub l. These values are reasonable, and are validated by the stiffness values from the optimization closely matching published values for each ligament's stiffness.


Optimization of Ligament Parameters on a Subject-specific Computational Human Knee Model in a Dynamic Knee Simulator Using Design of Experiments Related Books

Optimization of Ligament Parameters on a Subject-specific Computational Human Knee Model in a Dynamic Knee Simulator Using Design of Experiments
Language: en
Pages: 68
Authors: Paul Michael Wilson
Categories: Biomechanics
Type: BOOK - Published: 2011 - Publisher:

DOWNLOAD EBOOK

The objective of this study was to optimize ligament parameters used in a dynamic three dimensional subject-specific computational knee model. The parameters of
Development and Validation of a Subject-specific Computational Human Knee Model in a Dynamic Knee Simulator to Include Ligament and Tendon Bone Wrapping
Language: en
Pages: 136
Authors: Katherine Ann Weimer
Categories:
Type: BOOK - Published: 2007 - Publisher:

DOWNLOAD EBOOK

The objective of this study was to develop a dynamic three-dimensional subject-specific computational knee model and to validate the model using experimental da
Using Dynamic in Vivo Kinematics for Subject-specific Calibration of Knee Ligament Parameters
Language: en
Pages: 51
Authors: Stephen Nelson
Categories: Artificial knee
Type: BOOK - Published: 2021 - Publisher:

DOWNLOAD EBOOK

"In vivo clinical studies are the optimal way to investigate the biomechanical outcomes of new prosthetic devices. This particular style of testing can be diffi
A Musculoskeletal Model of a Subject Specific Knee Joint with Menisci, During the Stance Phase of a Walk Cycle
Language: en
Pages: 75
Authors: Mohammad Kia
Categories: Electronic dissertations
Type: BOOK - Published: 2011 - Publisher:

DOWNLOAD EBOOK

Movement simulation and musculoskeletal modeling can predict muscle forces, but current methods are hindered by simplified representations of joint structures.
Subject Specific Computational Models of the Knee to Predict Anterior Cruciate Ligament Injury
Language: en
Pages: 227
Authors: Bhushan S. Borotikar
Categories: Anterior cruciate ligament
Type: BOOK - Published: 2009 - Publisher:

DOWNLOAD EBOOK

Knee joint is a complex joint involving multiple interactions between cartilage, bone, muscles, ligaments, tendons and neural control. Anterior Cruciate Ligamen